Vol.24, No.2, 2024, str. 217–221
UDK

ANALIZA OŠTEĆENJA I OBNAVLJANJE INTEGRITETA RADNOG KOLA PELTON TURBINE NAKON REPARATURNGO ZAVARIVANJA: STUDIJA SLUČAJA

Milan Miladinov1, Branislav Đorđević2, Simon Sedmak2, Ciprian Bratu3, Dorin Radu3, Aleksandar Sedmak4, Nikola Aleksić5

1) Metal Rehabilitation and Testing Ltd, Belgrade, SERBIA

*email: 

2) Innovation Centre of the Faculty of Mechanical Engineering, Belgrade, SERBIA

3) Transilvania University of Brașov, Faculty of Civil Engineering, Brașov, ROMANIA

4) University of Belgrade, Faculty of Mechanical Engineering, Belgrade, SERBIA

5) Bauer Magyarorszag Specialis, Budapest, HUNGARY

 

Izvod

U ovom radu je prikazana tehnologija reparaturnog zavarivanja lopatice radnog kola Pelton turbine, kao i analiza oštećenja izazvana kavitacijom. Ekstremni radni uslovi doveli su do nastanka, a kasnije i do širenja prsline na lopatici, dužine 200 mm otkrivene na redovnom godišnjem pregledu čime je narušen integritet Pelton turbine. Osnovni materijal Pelton turbine, čelik X3CrNiMo13-4, ali i sama geometrija lopatice turbine, zahtevali su posebnu pažnju prilikom definisanja tehnologije reparaturnog zavarivanja. U tu svrhu primenjena je austenitna elektroda, a definisana i sprovedena tehnologija zavarivanja treba da predupredi nastanak novih prslina na istom mestu. Nakon NDT kontrole, radno kolo Pelton turbine je vraćeno u eksploataciju uz odgovarajuće preporuke za dalji monitoring.

Ključne reči: reparaturno zavarivanje, Pelton turbina, čelik X3CrNiMo13-4, analiza oštećenja

rad u celosti (547 kB)