Vol.18, No.3, 2018, pp.181–183 |
INTEGRITY ASSESSMENT OF TURBINE FLAT COVER PIPE Aleksandar Milovanović1, Aleksandar Sedmak1 1University of Belgrade, Faculty of Mechanical Engineering, Serbia asedmak@mas.bg.ac.rs |
Abstract
The turbine flat cover pipe (dimension ⌀219.1×12.7 mm, and material STPG-38) is tested and cracks are found. Determination of the required wall thickness for a pipe exposed to internal pressure is done according to EN 13480: 3-2012. An analytically determined stress intensity factor for the analysed crack is compared with the critical value of the stress intensity factor to assess the integrity of the analysed structure.
Keywords: structural integrity, stress intensity factor, turbine flat cover pipe, pipe wall thickness calculatione |
full article (389 kB) |