Vol.7, No2, 2007, pp. 133-140
UDC 620.169.1:697.326

ANALYSIS OF TEST RESULTS OF HOT–WATER BOILER AS A BASIS FOR ITS INTEGRITY ASSESSMENT

Vera Šijački Žeravčić, Gordana Bakić, Miloš Đukić 1

Biljana Anđelić 2

1) Faculty of Mechanical Engineering, University of Belgrade

2) Technical Faculty, University of Kragujevac, Serbia

Abstract

Assessment of service availability and integrity of power plant component materials requires the use of methodological approach, that includes service history data acquisition and analysis; defining a programme for material state non-destructive and destructive testing; and formulating acceptance criteria. Data based on boiler service history and on previous test results, comparing the new results to adopted acceptance criteria served as a basis for integrity assessment of hot-water boiler at plant “Mirijevo”, belonging to JKP “Beogradske elektrane”. Following the integrity assessment of critical boiler piping system parts, a proposal is defined for partial replacement of boiler wall tubes and a sequence of service recommendations how to prevent appearance of wall tubing damage is also given.

Keywords: hot-water boiler, non-destructive tests, destructive tests, integrity assessment, corrective and preventive measures